Cyberuptive

Ivanti's New KEVs: Is the Patch Complete?

By Chuck Lerch, Founder and CEO, Cyberuptive ·

Ivanti Connect Secure owners should confirm every appliance runs a fixed release, then investigate whether it was compromised before updating. (Belgium advisory) On October 30, 2026, CISA added two newly exploited flaws to its Known Exploited Vulnerabilities (KEV) Catalog, as documented in its CISA alert. Patching alone does not establish that prior access did not occur.

The October 30 additions mean owners should validate both software versions and security history, not simply confirm that an update was installed. (Belgium advisory) The Cybersecurity and Infrastructure Security Agency (CISA) listed two Ivanti Connect Secure vulnerabilities based on evidence of active exploitation. (CISA alert) The available guidance also warns that fixing a device does not undo a compromise that may already have happened. (Belgium advisory)

What are the key takeaways?

  • Check each appliance against the fixed-version thresholds for its Ivanti Connect Secure release train. (Belgium advisory)
  • Review device history and investigate signs of intrusion, including activity before the update.
  • Patch promptly, but treat patching and compromise response as separate workstreams. (Belgium advisory)

What did CISA add to the KEV Catalog?

CISA added CVE-2026-111357 and CVE-2026-118527 to its Known Exploited Vulnerabilities (KEV) Catalog on October 30, 2026, citing evidence of active exploitation, according to the CISA alert. The catalog is a public record of vulnerabilities known to be exploited in the wild. The additions concern Ivanti Connect Secure, a remote access product, and warrant prompt review of affected appliances.

The Centre for Cybersecurity Belgium says Ivanti updated its advisory to address both issues and that the flaws were chained with a previously disclosed authentication bypass. The agency reports that the chain could enable pre-authentication remote code execution (RCE), meaning code execution over a network without first authenticating. See our earlier authentication-bypass coverage for background on that part of the chain; the October 30 additions are separate issues and should be assessed on their own.

Which fixed versions should owners verify?

According to the Belgium advisory, the affected software is Ivanti Connect Secure before versions 25.1.1.3 and 22.8R2.6. Confirm the installed version on every appliance and compare it with the appropriate fixed threshold for that release train. Do not assume an earlier update for the authentication-bypass issue also resolves these newly listed vulnerabilities.

CheckProposed verification
Asset scopeList all Connect Secure appliances, including internet-facing and standby units.
Installed buildRecord the version on each appliance and match it to the correct release train.
Fixed thresholdVerify version 25.1.1.3 or later, or 22.8R2.6 or later, as applicable.
Update statusDocument the update and confirm the appliance reports the intended build afterward.

Organizations may use their normal patch-management process to coordinate testing, deployment, and version verification. The Centre for Cybersecurity Belgium recommends installing updates for vulnerable devices with high priority after thorough testing; that is guidance to balance urgency with operational checks.

What should teams investigate beyond the patch?

They should assess whether an appliance may have been accessed before the update, because a fixed version does not prove that the system was clean beforehand. The Belgium advisory specifically warns that patching may protect against future exploitation but does not remediate historical compromise. Review available appliance, identity, and network records for suspicious activity across the relevant period, preserve evidence, and escalate unexplained findings for incident response. Do not infer that an appliance was compromised solely because it was vulnerable, or that it was safe solely because it is now patched.

A practical response plan could assign one owner to verify builds and another to review security history, then record decisions and unresolved questions. If evidence suggests intrusion, follow the organization’s incident process and seek qualified assistance. Teams considering external monitoring can use this managed SOC pricing guide as background when assessing service options; it is not a substitute for investigating a potentially affected appliance.

What should owners do next?

Prioritize exposed or otherwise high-risk appliances for version confirmation and timely updates, while keeping investigation and remediation tasks distinct. The Belgium advisory describes one issue as privilege escalation and the other as the ability for an authenticated remote attacker to upload attacker-controlled content to a known location. It also reports that the two were chained with the earlier authentication bypass. These details support treating the appliances as security-sensitive, but do not establish that every vulnerable installation was attacked.

From a U.S.-based security operations center (SOC), we would pair appliance version evidence with an investigation of the period before the update. We would assign separate owners for patch verification and incident triage, record unavailable logs as a limitation, and escalate unresolved integrity concerns rather than treating the installed version as a clean bill of health.

What else should buyers and operators know?

Does installing the update prove the appliance was not compromised?

No. Updating can address future exposure, but the Belgium advisory cautions that patching does not remediate historical compromise. (Belgium advisory) Review relevant device and security records independently of version verification. (Belgium advisory)

Which versions does the Belgium advisory identify as fixed?

It lists 25.1.1.3 and 22.8R2.6 as the thresholds. (Belgium advisory) Confirm which release train applies to each appliance and verify the installed build against that threshold. (Belgium advisory)

Does an earlier Ivanti update necessarily cover these additions?

No such assumption is supported by the supplied advisories. Treat the newly listed vulnerabilities separately, check the current build against both thresholds, and verify the relevant vendor guidance. (Belgium advisory)

What if an appliance shows signs of possible intrusion?

Follow your incident-response process, preserve relevant evidence, and escalate for investigation. The Belgium advisory recommends increased monitoring and detection and reporting an incident when one occurs. (Belgium advisory)

What is the next step for your organization?

Bring your scope, current evidence, and unresolved responsibilities to a focused discussion. Schedule a security review or Call 833-92-CYBER to clarify the next practical actions.